Vertiv Liebert GXT MT+ CX 1 kVA LB 16A is a true on-line UPS that delivers continuous, high-quality AC power to connected equipment with no interruption when transferring to battery. It provides protection from blackouts, Brownouts, sags, surges, or noise interference. Features • Capacity: 1 kVA • IGBT Based Rectifier • Inbuilt 1100W charger: Inbuilt 1100W Charger and settable as per the battery capacity and compatible to Tubular battery also. • True Online Double Conversion with DSP Control Technology for High Performance and Reliability • New Graphical LCD Display provides UPS data, alarms and helps in faults diagnostic and trouble shooting • Double Conversion Efficiency upto 90% • Active Input Power Factor Correction 0.99 • 0.8 Output Power Factor • Wide Input Voltage window (110 – 280Vac) for Indian environmental condition and for optimized battery performance • Configurable Output Voltage (200/208/220/230/240Vac) • Generator compatible with wide input • Frequency Range (40 Hz-70 Hz) • 8 Stage extendable charging design for optimized Battery performance • Adjustable battery charging current 2/4/6/8/10/12/14/16 Amps according to battery capacity rating • 50/60 Hz automatic frequency converter mode • Intelligent monitoring with standard RS232/USB port plus slot available for RS485/Dry Contact/SNMP card • Inbuilt OVCD (Over Voltage Cut-off device) Benefits • Remote monitoring is available through USB/RS232 and optional via dry contacts and SNMP • The monitoring option software support TCP/IP with event log and analysis function • Self-diagnosis and protection enable the auto shutdown of the client terminal or server auto shutdown of the client terminal or server under abnormal mains supply or when battery is over discharged • SNMP Manager Card with advanced view power software (optional): allows remote monitoring through RJ45 & manages multiple UPS from anywhere through internet • Data logging real time dynamic graphs of UPS data, warning notification via audible alarm, broadcast, mobile message, e-mail & SNMP traps • Also supports optional environmental monitoring detector for temperature, humidity, and smoke. Password security protection and remote access management

Specifications

Full Protection Full protection from damaging power problems like Outages, Sags, Surges, Spikes, Noise, Transient, Frequency Deviation, Under-Voltage, Over-Voltage, Harmonics, etc
Model GXT MT+ CX 16A
PHASE Single phase with ground
CAPACITY (kVA) 1 kVA
CAPACITY (kW) 0.80 kW
INPUT Parameters
Nominal Voltage 200/208/220/230/240VAC
Input Voltage Range 110-280 VAC (Based on load at 50%)
Frequency Range 40Hz - 70 Hz
Power Factor 0.99 @ Nominal Voltage (100% load)
OUTPUT Parameters
Output Voltage 200/208/220/230/240VAC
Voltage Regulation ± 1%
Frequency Range (Synchronized Range) 47— 53 Hz or 57 — 63 Hz
Frequency Range (Batt. Mode) 50 Hz or 60Hz ± 0.1 Hz
Current Crest Ratio 3:1
Harmonic Distortion 3 % THD (Linear Load)
Transfer Time - AC to DC Zero
Transfer Time - Inverter to Bypass 4 ms (Typical)
Transfer Time - Waveform (Batt. Mode) Pure Sinewave
EFFICIENCY
To AC Mode 90%
To Battery Mode 85%
BATTERY Parameters
Battery Type Depending on the capacity of external batteries
Numbers 3
Charging Current (max.) 2.0A/4.0A/6.0 A/8.0/10.0/12.0/14.0/16.0A by default
Charging Voltage 41.0VDC ± 1%
INDICATORS
LCD Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continously sounding
PHYSICAL
Dimension, DxWxH (mm) 282 x 145 x 333
Net Weight (kgs) 5.6
ENVIRONMENT
Humidity 0-95 % RH @ 0- 50°C (non-condensing)
Noise Level Less than 45dBA @ 1 Meter
MANAGEMENT
Smart RS-232/USB Supports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP manager and web browser
T&C
Warranty 2 Years on UPS
Vetiv T&C * Derate to 80% of capacity in Frequency converter mode, the output voltage is adjusted to 100/200/208VAC and the ambient temperature between 450 to 500. / ** Product specifications are subjected to change without further notice