Vertiv Liebert GXT MT+ CX 1 kVA LB 16A is a true on-line UPS that delivers continuous, high-quality AC power to connected equipment with no interruption when transferring to battery. It provides protection from blackouts, Brownouts, sags, surges, or noise interference. Features • Capacity: 1 kVA • IGBT Based Rectifier • Inbuilt 1100W charger: Inbuilt 1100W Charger and settable as per the battery capacity and compatible to Tubular battery also. • True Online Double Conversion with DSP Control Technology for High Performance and Reliability • New Graphical LCD Display provides UPS data, alarms and helps in faults diagnostic and trouble shooting • Double Conversion Efficiency upto 90% • Active Input Power Factor Correction 0.99 • 0.8 Output Power Factor • Wide Input Voltage window (110 – 280Vac) for Indian environmental condition and for optimized battery performance • Configurable Output Voltage (200/208/220/230/240Vac) • Generator compatible with wide input • Frequency Range (40 Hz-70 Hz) • 8 Stage extendable charging design for optimized Battery performance • Adjustable battery charging current 2/4/6/8/10/12/14/16 Amps according to battery capacity rating • 50/60 Hz automatic frequency converter mode • Intelligent monitoring with standard RS232/USB port plus slot available for RS485/Dry Contact/SNMP card • Inbuilt OVCD (Over Voltage Cut-off device) Benefits • Remote monitoring is available through USB/RS232 and optional via dry contacts and SNMP • The monitoring option software support TCP/IP with event log and analysis function • Self-diagnosis and protection enable the auto shutdown of the client terminal or server auto shutdown of the client terminal or server under abnormal mains supply or when battery is over discharged • SNMP Manager Card with advanced view power software (optional): allows remote monitoring through RJ45 & manages multiple UPS from anywhere through internet • Data logging real time dynamic graphs of UPS data, warning notification via audible alarm, broadcast, mobile message, e-mail & SNMP traps • Also supports optional environmental monitoring detector for temperature, humidity, and smoke. Password security protection and remote access management
| Full Protection | Full protection from damaging power problems like Outages, Sags, Surges, Spikes, Noise, Transient, Frequency Deviation, Under-Voltage, Over-Voltage, Harmonics, etc |
| Model | GXT MT+ CX 16A |
| PHASE | Single phase with ground |
| CAPACITY (kVA) | 1 kVA |
| CAPACITY (kW) | 0.80 kW |
| INPUT Parameters | |
| Nominal Voltage | 200/208/220/230/240VAC |
| Input Voltage Range | 110-280 VAC (Based on load at 50%) |
| Frequency Range | 40Hz - 70 Hz |
| Power Factor | 0.99 @ Nominal Voltage (100% load) |
| OUTPUT Parameters | |
| Output Voltage | 200/208/220/230/240VAC |
| Voltage Regulation | ± 1% |
| Frequency Range (Synchronized Range) | 47— 53 Hz or 57 — 63 Hz |
| Frequency Range (Batt. Mode) | 50 Hz or 60Hz ± 0.1 Hz |
| Current Crest Ratio | 3:1 |
| Harmonic Distortion | 3 % THD (Linear Load) |
| Transfer Time - AC to DC | Zero |
| Transfer Time - Inverter to Bypass | 4 ms (Typical) |
| Transfer Time - Waveform (Batt. Mode) | Pure Sinewave |
| EFFICIENCY | |
| To AC Mode | 90% |
| To Battery Mode | 85% |
| BATTERY Parameters | |
| Battery Type | Depending on the capacity of external batteries |
| Numbers | 3 |
| Charging Current (max.) | 2.0A/4.0A/6.0 A/8.0/10.0/12.0/14.0/16.0A by default |
| Charging Voltage | 41.0VDC ± 1% |
| INDICATORS | |
| LCD | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
| ALARM | |
| Battery Mode | Sounding every 4 seconds |
| Low Battery | Sounding every second |
| Overload | Sounding twice every second |
| Fault | Continously sounding |
| PHYSICAL | |
| Dimension, DxWxH (mm) | 282 x 145 x 333 |
| Net Weight (kgs) | 5.6 |
| ENVIRONMENT | |
| Humidity | 0-95 % RH @ 0- 50°C (non-condensing) |
| Noise Level | Less than 45dBA @ 1 Meter |
| MANAGEMENT | |
| Smart RS-232/USB | Supports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC |
| Optional SNMP | Power management from SNMP manager and web browser |
| T&C | |
| Warranty | 2 Years on UPS |
| Vetiv T&C | * Derate to 80% of capacity in Frequency converter mode, the output voltage is adjusted to 100/200/208VAC and the ambient temperature between 450 to 500. / ** Product specifications are subjected to change without further notice |