Liebert GXT MTX+ 6 kVA is a full featured Transformer based UPS designed to offer compact efficient and reliable power thirsty modern electronic gadgets. The Liebert GXT MTX+ 6 kVA is compact UPS System with best-in-class Online UPS technology suited for critical applications such as IT & Communication Equipments, VolP, Small/Medium Data Centre, Server Rooms, ATMs etc. Features & Benefits: • Rating: 6 kVA / 4.80 kW • Model: GXT MTX+ 6 kVA • Phase: 1 Phase IN / 1 Phase OUT • I/P Voltage: 230 Vac (1 Ph+ N) • O/P Voltage: 208**/220/230/240 VAC • Inbuilt Isolation Transformer • IGBT Based Rectifier. • True Online Double Conversion with DSP Control Technology for High Performance and Reliability. • New Graphical LCD Display Provides UPS Data, Alarms and Helps in faults diagnostics and troubleshooting. • Double Conversion Efficiency upto 84%. • Active Input Power Factor Correction 0.99. • Output Power Factor: 0.8 • Wide Input Voltage window (110 — 300 Vac) for Indian Environmental Condition and for Optimized Battery Performance. • Adjustable Battery Configuration from 16*/18*/20 pcs and Digital battery Charger with Adjustable Charging Current (0.5 Amps to 6 Amps) Via LCD Display. • 3 Stage Extendable Charging Design for the Optimized Battery Performance. • CE and ROHS Compliance.

Specifications

Isolation Transformer Inbuilt
Technical Specifications
Model GXT MTX+ 6 kVA
Capacity (kVA) 6 kVA
Capacity (kW) 4.80 kW
Phase 1 Phase IN - 1 Phase OUT
Input
Voltage Range
Low Line Loss 110 VAC ± 3% at 50% Load / 160 VAC ± 3% at 100% Load
Low Line Comeback Low Line Loss Voltage +10V
High Line Loss 300 VAC ± 3%
High Line Comeback High Line Loss Voltage - 10V
Frequency Range 46Hz ~ 54Hz @ 50Hz system / 56Hz ~ 64Hz @ 60Hz system
Phase Single phase with ground
Power Factor ≥ 0.99 @ 100% load
Output
Output Voltage 220/230/240VAC
Ac Voltage Regulation ± 1%
Frequency Range (Synchronized Range) 46 Hz ~ 54 Hz @ 50Hz system or 56 Hz ~ 64 Hz @ 60Hz system
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Power Factor 0.8
Overload
AC Mode 100% ~ 105%: 10min, 105% ~ 125%: 1min, >125% : 1sec
Battery Mode 100% ~ 105%: 30sec, 105% ~ 125%: 10sec, >125% : 1sec
Current Crest Ratio 3:1 max
Harmonic Distortion 3 % @ 100% Linear Load : 7% @100% Non-Linear Load
Transfer Time
Line to Battery 0 ms
Inverter to Bypass 0 ms
Configuration Standalone / Hot-Standby
AC Mode >84%
Battery Mode >83%
Battery
Type Lead acid/Tubular/Li-ion
Numbers 16-20 Derating capacity = original real power capacity X N/20
Charging Current Default: 4 A ± 10% / Max.: 6A ± 10% (settable)
Charging Voltage 13.65 V ±1%
Physical
Dimension, D x W x H (mm) 369x190x630
Net Weight (kgs) 72
Environment
Operation Temperature 0 ~ 40C (battery life cycle will be shorten when temperature is above 25C)
Operation Humidity <95 % and non-condensing
Operation Altitiude <1000m
Acoustic Noise Level Less than 65dBA @ 1 Meter
Management
Smart Rs-232/Usb Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC
Optional Snmp Power management from SNMP manager and web browser
T&C
Warranty 1 Year on UPS
Vertiv T&C * Product specifications are subject to change without further notice **Derate capacity to 90% of capacity when the output voltage is adjusted to 208VAC ** *When using batteries from 16-19, the unit will be de-rate according to formula ; P= Prating X N/20