Pune
08048041593
+917775988753
Single Phase UPS by Vertiv

Vertiv Liebert ITA2 UPS 1-3 kVA

INR 35144
In stockcod not available
Phone Number

08048041593

Please keep 0 before dialling the number.

Email Address originatepower@gmail.com

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Address Flat. B-06 , 2nd Floor , Sanco Elegance, Moshi

Pune, India, 412105

Description

The Vertiv Liebert ITA2 (1-3 kVA) series is a full-featured transformer-free UPS designed to offer compact, efficient, and reliable power to modern sensitive electronic equipment. • True online double Conversion UPS • Available in 1-3 kVA Capacity • I/P Voltage: 230 VAC • O/P Voltage: 220 Vac/230 Vac/240 Vac, 220 Vac by default • Output Power Factor: Unity (1) i.e. kVA=kW • IGBT based Double conversion PWM based online UPS • Gravity Sense LCD display • Wide Input Voltage Range • Input Power Factor Correction • Smart battery charger design for optimized battery performance • Generator Compatible • SNMP, USB, and RS232 Multiple communication • Emergency Power Off Function • Rack-tower design for installation flexibility • Turnkey dust-resistant design with the ability to operate under high ambient temperature of up to 50 °C • Integrated output sockets • Highly-efficient delivers efficiency up to 94% in Double Conversion Mode • Delivers efficiency up to 98% in Eco Mode • Adopts to any harsh grid environments (100 Vac to 288 Vac) • Intelligent battery management system • Small form factor (2U) and Available in rack and tower configurations • Built-in Ethernet port for web-page monitoring • Built-in input and output dry contacts • Innovative air channel and Moisture and Dust-proof Design • Two-way LLC circuit topology • Operation up to 50 °C environment • High Input Power Factor for harsh power grid environment • UPS Warranty: Standard 2 years warranty. Available in both Standard Backup (SB) and Long Backup (LB) Variant.

Configuration 1 Phase IN - 1 Phase OUT
Applications Applications • PCs and Workstations • Small/Medium server rooms • Edge data center • Network Closet • VoIP Telecom
BIS Certification Yes
ENERGY STAR certified 2011/65/EU uninterruptible power supplies version 1.0 program requirements/ENERGY STAR UPS version 1.0 test method guidance
RoHS Yes
Surge Protection IEC/EN 61000-4-5
Electromagnetic Compatibility (EMC) Conducted Emission:IEC/EN 62040-2 C2, Harmonic current:IEC/EN 61000-3-2
Safety (CE) IEC/EN 62040-1:2008+A1:2013
MODBUS Optional through SIC card
Dry Contacts Built-in
Ethernet Port Built-in. Supports HTTP and SNMP protocol
USB Port Built-in
Intelligent Card Port Optional. Can be used for connecting RDU SIC card/SIC card
Cable Entry Rear
Ingress Protection Level IP20
Ventilation Forced-air cooled
Altitude ≤3000 m; derating when higher than 3000 m
Relative Humidity 5% RH to 95% RH, non-condensing
Storage Temperature 20 °C to +60 °C (battery excluded); -15° C to +40°C (battery included)
Operating Temperature 0 °C to 50 °C, Linearly Derates to 90% and 80% capacity at 40 °C and 50 °C respectively
Display Type Colorful Gravity Sense LCD display
Acoustic Noise Level < 50 db
Inverter-Bypass Transfer Time Synchronous transfer: less than 1 ms
Transfer Time Mains - Battery 0 ms
Battery Type Sealed, lead-acid, maintenance-free battery
Mains Efficiency / AC-AC 92% to 94%
ECO Mode Efficiency 98%
Output Overload Capacity on Battery Mode 105% to 125% for 1 min; above 125% for 200 ms
Output Overload Capacity on Normal Mode 105% to 125% for 10 min; 125% to 150% for 1 min; above 150% for 200 ms
Output Voltage Harmonic Distortion < 1% (linear load), < 3%(Non-Linear Load)
Output Crest Factor 3 : 1
Output Rated Power Factor Unity
Output Frequency Track Rate Default: 0.5 Hz/s; Configurable range: 0.2 Hz/s; 0.5 Hz/s; 1 Hz/s (single UPS)
Output Frequency Synchronization Range Rated frequency ±3 Hz; Configurable range: ±0.5 Hz to ±5 Hz
Output Voltage 220 Vac/230 Vac/240 Vac, 220 Vac by default
Output Rated Power 1 kW - 3 kW
Input Power Factor ≥ 0.99 at full load; ≥ 0.97 at half load; ≥ 0.94 at 30% load
Input Frequency Range 40 Hz to 70 Hz
Input Rated Frequency 50 Hz
Input Volatge Range 176 Vac to 288 Vac at full load; 100 Vac to 176 Vac linear increasing; 100 Vac at half load
Rated Voltage 220 Vac
Installation Mode Rack/Tower
Technology IGBT based Double conversion PWM based online UPS
Rating 1 kVA -3 kVA
Model Vertiv Liebert ITA2